How to use this tool
- Enter first resistance, second resistance.
- Select Calculate to view the result.
- Check the method and assumptions below before using the result.
Input reference and sample values
Use the units and choices shown for each field. Sample values are provided for practice, not as recommendations.
| Input | Format and units | Sample |
|---|---|---|
| First resistance | Numeric value. Unit: Ω. Must be greater than zero. | 100 |
| Second resistance | Numeric value. Unit: Ω. Must be greater than zero. | 200 |
Result for these sample inputs
-2 ×
Select Try the example in the form to load these values and calculate them again. This replaces the current form inputs. Compare the result with the method and worked explanation below.
The method, explained
Gain = −feedback resistance R2/input resistance R1.
Using first resistance = 100 Ω, second resistance = 200 Ω, the result is -2 ×. Change these example inputs to match your task; use the method above to check each step.
What to keep in mind
Assumes negative feedback and operation within supply rails and bandwidth. Ideal-component calculation for study and estimation. It does not select safe wiring, protective devices or component ratings for an installation.
Methodology maintained by ClarityKit. How these tools are built and checked.